nvent enlogic
en6000 metered switched pdu

The nVent enLogic Outlet Metered, Outlet Switched PDU combines complete energy & power metering, environmental & access monitoring, and remote outlet on/off switching for complete protection and control in critical environments. Outlet power-up sequencing protects against inrush current overload and allows users to define equipment boot-up order and timing, while billing-grade outlet level metering provides detailed equipment level power data. Advanced network management features allow for a variety of remote access methods and integration with accessories including environmental monitoring and security access solutions.

Please scroll to the bottom of this page to view a list of available EN6000 series PDUs.

Stringent Cyber Security Assurance

Enlogic Advantage Series power distribution unit (PDU) products have recently earned certification to UL 2900 through the UL Cybersecurity Assurance Program (UL CAP).   

At nVent, we believe that safer systems ensure a more secure world, and this certification demonstrates our commitment to products that are hardened against potential cyber threats. Enlogic by nVent PDUs are among the first in the data solutions industry to achieve UL 2900 certification for data center PDUs.  

“Data and systems security is imperative in data center applications. Every network-connected device is a possible attack point for cyber criminals with the potential for data loss and downtime of key operations in infrastructure, medical and financial systems,” stated Shubhayu Chakraborty, president of nVent CIS Global by nVent. “Ensuring the Enlogic power distribution products are hardened to cyber threats is imperative to our customers’ threat mitigation.” 

UL2900 certification specifies the methods by which a product is evaluated and tested for the presence of vulnerabilities, software weaknesses and malware. It has been adopted as an American National Standards Institute (ANSI) standard. The standard includes requirements and methods to evaluate and test network-connectable products, including: 

As the world becomes more sustainable and electrified and global demand for data continues to grow, we will continue to develop innovative solutions to connect, protect and manage heat in critical systems for our data solutions customers. From energy-efficient cooling solutions to keeping operations safe from cyber threats, we are ready to meet our customers’ ever-changing needs.  

User Customisable Coloured LED Border

Almost all data center industry experts agree that color-coding PDUs are valuable to operation and overall maintenance of your data center and connected equipment. The benefits of colored PDUs are:

The Problem

And while data center management professionals overwhelmingly agree that color coding redundant power sources in a data center cabinet is beneficial, there are still drawbacks associated with colorizing PDUs:

The Enlogic Solution

Enlogic’s EN2.0 PDUs offer the industry’s quickest, and most cost-effective solution that allows users to configure custom-colored PDUs. Our Patent Pending technology comes standard on all EN2.0 PDUs and allows users to customize and change the NMC color quickly and easily to differentiate redundant power sources, reduce human error, and simplify data center operations.

The NMC color is easily configured on the NMC interface or using Enlogic’s simple web interface. Users can select from any of the bright, highly visible NMC colors: blue, red, green, yellow, magenta, cyan, white, and black. Customization of your PDUs has never been easier with Enlogic’s EN2.0.  

However, for users who are still looking to further customize their PDU chassis with any of our custom powder-coated colors, Enlogic makes the process simple and streamlined with quicker lead times than competitors.

DC Power Sharing for Always on Network & Sensor Communication

Advanced Network Management

Network Connectivity: Dual ports: 1x Gigabit Ethernet (10/100/1000 Mbps) and 1x (10/100 Mbps) connection/IP address

Ethernet Cascading: Up to 64 units share a single “daisy-chain” Ethernet connection/IP address

DC Power Sharing: Each PDU can provide DC power sufficient to power network management electronics and sensors in a neighbouring PDU in the event of AC power source loss

Dual Ethernet Support: Dual Ethernet ports for redundant communication

Dual Network Access: Dual network connectivity allows redundancy and Multiple stack holder connectivity for up to 64 units in Ethernet cascading mode

Remote Connectivity: HTTP(s), iPV4 and iPV6, SSH, Virtual Serial, SNMP (v1, v2c, v3), JSON-RPC, LDAP(S), FTP/SFTP, RADIUS, Redfish DMTF RESTful API

WebUI Interface: Data efficient REACT framework with native mobile device support

High Accuracy Metering

Metering Attributes: Voltage(V), Current(A), Apparent Power(kVA), Real Power(kW), Power Factor, Energy (kWh)

Metering Accuracy: ± 1% to ISO/IES 62052-21

Hot-Swap Network Management Module

Microprocessor/Memory: Cortex A-5

Field Replacement: Hot swap replaceable module; fast plug-and-play connectivity

Module Orientation: Tool-less removal and 180⁰ install capable for top or bottom power cord orientation

User Display: Dual Displays: large high visibility LED display for key metering information and alarms. Low-power graphical oLED with user controls for local information.

Display Language: English, Spanish, German, French, Italian, Korean, Japanese, Chinese (simplified)

Lighted Color Code: User programmable color border allows power source identification by PDU

Sensor and Security Supports up to 8 digital sensors for environmental sensors and/or electronic locks
Support:

Temperature and Humidity Sensors

Fluid Leak Sensors

Other Sensors & Accessories

EN6000 SERIES

Outlet Metered & Outlet Switched Intelligent Rack PDU

EN6325 - 1-ph 32A 230V 20x C13 & 4x C19 Outlets

EN6329 - 1-ph 32A 230V 24x C13 & 8x C19 Outlets

EN6402 - 3-ph 16A 400V 18x C13 & 6x C19 Outlets

EN6808 - 3-ph 32A 400V 12x C13 & 12x C19 Outlets

EN6810 - 3-ph 32A 400V 24x C13 & 12x C19 Outlets